The INFLEX® battery operated pump represents a major break through in
pumping technology delivering many of the benefits of peristaltic style
pumps but incorporating significant improvements in battery life, tube
life and containment.
EASE OF USE
The pump includes a digital push button display for ease of programming.
Using three primary screens, the user can quickly set the local time, the
time when the pump is to commence dispensing and the dispense volume.
SECURITY
The digital display includes a security feature that prevents unauthorised
users from changing the settings and thereby tampering with the dispensing
operation.
CHANGE OF BATTERIES
The pump incorporates both an audible and a visual alarm that the batteries
need changing. The process of changing the batteries is simple and convenient.
Once the unit is mounted on the wall, unscrew the retaining plate allowing the
battery compartment to be withdrawn and the four C-cell batteries to be replaced.
CHANGE OF PUMP HEAD
The pump head is a transparent sealed unit incorporating the tube and
therefore performance of the pump and the tube is easily monitored.
Replacement pump heads can be inserted and connected to delivery tubes
in a matter of seconds.
ALARMS
There are two alarms:
1. Battery condition warning - the beeper will sound (at five second intervals)
when the batteries require replacement. This is also indicated on the screen.
NB - when the battery alarm is operating the pump does not perform it's daily
dispense function.
2. Optional low chemical alarm - this alarm is designed to alert the fact that
under normal operating conditions the chemical container requires replacement.
The beeper will sound (at five second intervals) between the hours of 8 am and
noon daily and the screen will indicate 'replace jug now' continuously. After
replacement, the pump will require priming. This resets the alarm facility.
This alarm is preset at the factory and can be tailored to each customers needs.
- Audible and visual low battery alarms
- Low chemical alarm (optional)
- 24 hour clock
- Pump can run dry for extended periods without damage
- Integral valves with no moving parts
- Non siphoning valves
| Operating Voltage | 6 volts (4 x C cell alkaline batteries) |
| Battery Life | minimum 100 litres dispensed (open flow) |
| Maximum Usable Lift | 0.5 matre |
| Volume Throughput | 90mls per minute |
| Volume Program | 10ml increments (2ml optional) |
| Program | capable of multiple dispense times within a 24 hr period |
| Maximum Dose Setting | 990mls |
| Keypad | Security access (optional) |
| Dispensing Accuracy | 5% |
|